At the Askole AWS the DMA572 Lsi-Lastem Thermohygrometer is mounted on a 2 m pole. It is a probe for measuring air temperature and air relative humidity with replaceable sensitive element for simplify calibration and maintenance. LSI-Lastem supplies a precise and reliable set of probes, suitable for a continuous measurement in severe environments, in presence of deep thermal and hygrometric ranges with high sun radiant heat. An important feature of this set of sensor is that the thermohygrometric sensitive element is easily replaceable, in order to have a simple and rapid ordinary maintenance and avoiding calibration. The Thermohygrometer has supported a considerable improvement, owing to a deep technical and styling development process: a fan ensures a continuos air change around the sensor in order to eliminate temperature fault caused by radiant heat. For temperature: Range -30.+70°C Sensitive element Pt100 1/3 DIN-B Accuracy ± 0,1°C (0°C) Hysteresis&Repeatability na Resolution 0,025°C Long term stability -0.04% (after 5 years at 200°C) Calibration uncertainty 0,1°C Response time (T63) Wind speed 0,3-0,5 m/s: 80sec Radiation shield efficiency with respect to forced ventilation sensor (wind 0,5m/s, rad.800 W/m2): +0,6°C For relative humidity: Range: Nom.0..100%, Eff.10..98% Sensitive element Capacitive Accuracy 2,5% (11-90%) 0,6°C (20°C, 50%RH) Hysteresis&Repeatability 0,5% Resolution 0,2% Long term stability -2%/year (at 75%RH) n.a. Calibration uncertainty 0,1°C 1,5% na Response time (T63) Wind speed 0,3-0,5 m/s: 80sec Radiation shield efficiency with respect to forced ventilation sensor (wind 0,5m/s, rad.800 W/m2): n.a. General characteristic: Ventilation: Natural Electric output Jumper locally selectable 2 x 0-20 mA, 4-20 mA, 0-5 V, 1-5 V. 60-300 mV Output signals Output n.1: temperature. Output n.2: RH% or dew point (default RH%) Operating temperature -30°+70°C Sampling rate 1 sec. (default) PC programmable 1..300 sec. N°acquisitions for mobile average calculation: N°1 (default), PC programmable 1..20 acquisitions Load resistance (mA output): DMA570 300 Ohm
At the Pyramid Laboratory Observatory AWS the DMA570 Lsi-Lastem Thermohygrometer is mounted on a 2 m pole. It is a probe for measuring air temperature and air relative humidity with replaceable sensitive element for simplify calibration and maintenance.
The DMA572 Thermohygrometer by Lsi-Lastem was installed on 2008 at Kala Patthar. It is a probe for measuring air temperature and relative humidity with replaceable sensitive element for simplify calibration and maintenance. LSI-Lastem supplies a precise and reliable set of probes, suitable for a continuous measurement in severe environments, in presence of deep thermal and hygrometric ranges with high sun radiant heat. An important feature of this set of sensor is that the thermohygrometric sensitive element is easily replaceable, in order to have a simple and rapid ordinary maintenance and avoiding calibration. The Thermohygrometer has supported a considerable improvement, owing to a deep technical and styling development process: a fan ensures a continuous air change around the sensor in order to eliminate temperature fault caused by radiant heat.
A thermohygrometer DMA570 was installed at Urdukas Station. This sensor is manufactured by LSI-Lastem (Italy).The DMA 570 thermohygrometer is an instrument for measuring temperature and relative humidity and suitable for a continuous measurement in severe environments; in presence of deep thermal and hygrometric ranges with high sun radiant heat.
The Vaisala HUMICAP® Humidity and Temperature Probe HMP155 provides reliable humidity and temperature measurement. It is designed especially for demanding outdoor applications. Features/Benefits ▪ Vaisala HUMICAP®180R sensor - superior long-term stability ▪ Optional warmed humidity probe and chemical purge ▪ Plug-and-play ▪ USB connection for service use ▪ Fits with DTR13 and DTR503 radiation shields and also for a Stevenson screen ▪ Weather-proof housing IP66 ▪ Optional, fast temperature probe ▪ Different output possibilities: voltage, RS-485, resistive Pt100 ▪ Applications: meteorology, aviation and road weather, instrumentation
At the Pyramid Laboratory Observatory AWS the DMA570 Lsi-Lastem Thermohygrometer is mounted on a 2 m pole. It is a probe for measuring air temperature and air relative humidity with replaceable sensitive element for simplify calibration and maintenance.
At the Namche AWS the DMA570 Lsi-Lastem Thermohygrometer is mounted on a 2 m pole. It is a probe for measuring air temperature and air relative humidity with replaceable sensitive element for simplify calibration and maintenance. LSI-Lastem supplies a precise and reliable set of probes, suitable for a continuous measurement in severe environments, in presence of deep thermal and hygrometric ranges with high sun radiant heat. An important feature of this set of sensor is that the thermohygrometric sensitive element is easily replaceable, in order to have a simple and rapid ordinary maintenance and avoiding calibration. The Thermohygrometer has supported a considerable improvement, owing to a deep technical and styling development process: a fan ensures a continuos air change around the sensor in order to eliminate temperature fault caused by radiant heat. For temperature: Range -30.+70°C Sensitive element Pt100 1/3 DIN-B Accuracy ± 0,1°C (0°C) Hysteresis&Repeatability na Resolution 0,025°C Long term stability -0.04% (after 5 years at 200°C) Calibration uncertainty 0,1°C Response time (T63) Wind speed 0,3-0,5 m/s: 80sec Radiation shield efficiency with respect to forced ventilation sensor (wind 0,5m/s, rad.800 W/m2): +0,6°C For relative humidity: Range: Nom.0..100%, Eff.10..98% Sensitive element Capacitive Accuracy 2,5% (11-90%) 0,6°C (20°C, 50%RH) Hysteresis&Repeatability 0,5% Resolution 0,2% Long term stability -2%/year (at 75%RH) n.a. Calibration uncertainty 0,1°C 1,5% na Response time (T63) Wind speed 0,3-0,5 m/s: 80sec Radiation shield efficiency with respect to forced ventilation sensor (wind 0,5m/s, rad.800 W/m2): n.a. General characteristic: Ventilation: Natural Electric output Jumper locally selectable 2 x 0-20 mA, 4-20 mA, 0-5 V, 1-5 V. 60-300 mV Output signals Output n.1: temperature. Output n.2: RH% or dew point (default RH%) Operating temperature -30°+70°C Sampling rate 1 sec. (default) PC programmable 1..300 sec. N°acquisitions for mobile average calculation: N°1 (default), PC programmable 1..20 acquisitions Load resistance (mA output): DMA570 300 Ohm
The DMA572 Thermohygrometer by Lsi-Lastem was installed on 2008 at Kala Patthar. It is a probe for measuring air temperature and relative humidity with replaceable sensitive element for simplify calibration and maintenance. LSI-Lastem supplies a precise and reliable set of probes, suitable for a continuous measurement in severe environments, in presence of deep thermal and hygrometric ranges with high sun radiant heat. An important feature of this set of sensor is that the thermohygrometric sensitive element is easily replaceable, in order to have a simple and rapid ordinary maintenance and avoiding calibration. The Thermohygrometer has supported a considerable improvement, owing to a deep technical and styling development process: a fan ensures a continuous air change around the sensor in order to eliminate temperature fault caused by radiant heat.
The station records continuously measurements of the seven meteorological standard parameters: air temperature, relative humidity, wind speed and direction, atmospheric pressure, global solar radiation and total precipitation. A thermohygrometer DMA572 LSi-Lastem(Italy) measures : -air temperature (°C); - relative humidity(%).
At the Lukla AWS the DMA572 Lsi-Lastem Thermohygrometer is mounted on a 2 m pole. It is a probe for measuring air temperature and air relative humidity with replaceable sensitive element for simplify calibration and maintenance. LSI-Lastem supplies a precise and reliable set of probes, suitable for a continuous measurement in severe environments, in presence of deep thermal and hygrometric ranges with high sun radiant heat. An important feature of this set of sensor is that the thermohygrometric sensitive element is easily replaceable, in order to have a simple and rapid ordinary maintenance and avoiding calibration. The Thermohygrometer has supported a considerable improvement, owing to a deep technical and styling development process: a fan ensures a continuos air change around the sensor in order to eliminate temperature fault caused by radiant heat.