At the AWS Namche station the DQA035 Lsi-Lastem rain gauge is mounted on a 1,5 m mast.The station was installed on October 2001.This model of Rain gauge has a 1.000 cmq collector area.
Namche Station is part of the station network of automated measurement stations (AWSs) that were installed in the Eastern Himalayas: the AWSs are located at different altitudes, over a stretch oriented approximately 40 km south to north. At the AWS Namche station the CombiSD DNA022 Lsi-Lastem combined wind speed-direction sensor is mounted on a 5m pole. The CombiSD sensor includes, in a single apparatus, the both transducers for measuring wind speed and wind direction. Its use simplifies the installation and the plant design in respect of the sensors with separate measurements plus giving some other advantages being smaller, lighter and cheaper. The CombiSD DNA022: sensor has a direct signal output. Frequency (Hz) for wind speed and resistance (Ohm) for wind direction. the CombiSD has low power consumption, it can be used in systems with small energy availability.
Namche Station is part of the station network of automated measurement stations (AWSs) that were installed in the Eastern Himalayas: the AWSs are located at different altitudes, over a stretch oriented approximately 40 km south to north. At the AWS Namche station the CombiSD DNA022 Lsi-Lastem combined wind speed-direction sensor is mounted on a 5m pole. The CombiSD sensor includes, in a single apparatus, the both transducers for measuring wind speed and wind direction. Its use simplifies the installation and the plant design in respect of the sensors with separate measurements plus giving some other advantages being smaller, lighter and cheaper. The CombiSD DNA022: sensor has a direct signal output. Frequency (Hz) for wind speed and resistance (Ohm) for wind direction. the CombiSD has low power consumption, it can be used in systems with small energy availability. The CombiSD sensor includes, in a single apparatus, the both transducers for measuring wind speed and wind direction. Its use simplifies the installation and the plant design in respect of the sensors with separate measurements plus giving some other advantages being smaller, lighter and cheaper. The CombiSD DNA022: sensor has a direct signal output. Frequency (Hz) for wind speed and resistance (Ohm) for wind direction. the CombiSD has low power consumption, it can be used in systems with small energy availability. The technical characteristics are: - Principle of operation: 3 cups and vane anemometer - Speed sensor: Optoelectronic disk - Direction sensor: 2000 Ohm wire potentiometer / Positioning Hall effect sensor - Housing: Heavy gauge anodised aluminium - Shaft carriers: Low-torque stainless steel bearings - Protection (vertical position): IP65 - Mechanical mounting: On 48 50 mm diameter mast - Electrical outlet terminators: IP65 watertight connector - Weight (instrument with rotors): 950 gr. The Physical and operational specification are: - damage threshold > 75 m/s - operating temperature: -30°+70°C The speed measures are specified by: - Measurement range: 0-60 m/s (using transfer function) - Threshold: 0,21 m/s - Response time (63% at 5 m/s): 0.8 s - Distance constant (delay distance) at 5 m/s: 4 m - Resolution (integration time=1s): 0.05 m/s - Accuracy & Linearity: 0,1 m/s+1%VL (readout), if connected to LASTEM data loggers. The direction measures are specified by: - Measurement range: 0 ÷ 360 - Threshold: 0,15 m/s - Response time (at 5 m/s): 0,26 s - Delay distance (at 5 m/s): 1,32 m - Damping coefficient (VDI3786): 0,21 - Transfer function: Dir(°)= 355 x R(Ohm)/2000 - Resolution: 0,1 - Accuracy: 1% FS (Full scale) - Integral linearity: 0,5%
Wet depositions have been collected at the EVK2CNR Pyramid site, in Sagarmatha National Park. Daily and weekly samples have been collected during the monsoon season in 2007 and 2008. Ionic content, total nitrogen and low molecular weight organic acids have been analysed by Ion Chromatography and colorimetric methods.