Monte Curcio instruments. TSI CPC3775 - Condensation Particle Counter
Monte Curcio (MCU) instruments: TSI CPC3775 - Condensation Particle Counter. The Model 3775 is a general purpose counter that can detect airborne particles down to 4 nanometres in diameter. It provides highly accurate measurements over a wide concentration range from 0 to 107 particles per cubic centimetre. In the Model 3775, an aerosol sample is drawn continuously through a heated saturator where butanol is vaporized and diffuses into the aerosol sample stream. Together, the aerosol sample and butanol vapor pass into a cooled condenser where the butanol vapor becomes supersaturated and ready to condense. Particles present in the sample stream serve as condensation nuclei. Once condensation begins, particles quickly grow into larger droplets and pass through an optical detector where they are counted easily. The instruments uses a laser-diode light source and diode photodetector to collect scattered light from particles.
|
Citation proposal
Pirrone N. (CNR-IIA, Institute of Atmospheric Pollution Research). Monte Curcio instruments. TSI CPC3775 - Condensation Particle Counter. CNR-Institute of Atmospheric Pollution Research https://geoportal.mountaingenius.org/geonetwork/srv/api/records/mcu_inst_tsi_3775_pm |
Simple
- Date ( Creation )
- 2015-02-25
- Edition
- First
- Identifier
- mt_curcio / mcu_inst_tsi_3775_pm
- Purpose
- Assessment of environmental pollution
Principal investigator
- Maintenance and update frequency
- Not planned
- GEOSS Societal Benefit Areas, version 2.3
-
- Health
- GEMET - INSPIRE themes, version 1.0
-
- Environmental monitoring facilities , Human health and safety
- GEMET - Concepts, version 2.4
-
- pollution , pollutant
- GEMET - Groups, version 2.4
-
- CHEMISTRY, SUBSTANCES, PROCESSES
- GEOSS - Earth Observation Vocabulary, version 1.0
-
- ATMOSPHERIC CHEMISTRY , Contaminants/Pollutants (Inorganic/Organic)
- GEOSS - Societal Benefit Areas, version 1.0
-
- Global biogeochemistry , Human health , Pollution events
- EARTh - Environmental Applications Reference Thesaurus
-
- monitoring stations , pollution monitoring , environmental monitoring , monitoring network , air quality monitoring , pollutant monitoring
- Use limitation
- geossNoMonetaryCharge
- Access constraints
- Other restrictions
- Other constraints
- (e) intellectual property rights
- Spatial representation type
- Vector
- Denominator
- 1000
- Metadata language
- English
- Character set
- UTF8
- Topic category
-
- Environment
- Health
N
S
E
W
))
- Time period
- 2015-01-012015-01-01
- Reference system identifier
-
EPSG 4326
- Date ( Revision )
- 2009-10-15
- Distribution format
-
- unknown (unknown )
- OnLine resource
- Browser to MCU databases
- OnLine resource
- http://sdi.iia.cnr.it/mcugeoserver/ows?
- OnLine resource
- http://sdi.iia.cnr.it/gmosgeoserver/ows?
- Hierarchy level
- Dataset
Conformance result
- Date ( Publication )
- 2009-06-11
- Explanation
- See the referenced specification
- Pass
- true
- Statement
- Calibration of the instrument is performed by maintaining a stable “volumetric” flow through the sensor using a saphire orifice operating at a critical pressure drop. Stable critical flow through the orifice is achieved using a high vacuum diaphragm pump. Calibration is made annually.//Ref. Operation and Service Manual Model 3775 (http://www.tsi.com)
gmd:MD_Metadata
- File identifier
- mcu_inst_tsi_3775_pm XML
- Metadata language
- English
- Character set
- UTF8
- Hierarchy level
- Dataset
- Date stamp
- 2015-06-12T10:12:40
- Metadata standard name
- ISO 19115:2003/19139
- Metadata standard version
- 1.0
Overviews
Provided by

Views
mcu_inst_tsi_3775_pm
Access to the portal
Read here the full details and access to the data.
Associated resources
Not available