  Monte Curcio instruments. Tekran 1130 - Oxidized Mercury Speciation Module

Monte Curcio (MCU) instruments: Tekran 1130 Oxidized Mercury Speciation Module. The Model 1130 Oxidized Mercury Speciation Unit expands the Model 2537 Mercury Vapor Analyser capabilities to simultaneously monitor elemental and gaseous oxidized mercury (GOM and RGM) species in ambient air. It includes a Denuder module, a Pump module and the Zero Air Dryer Module. A specially coated annular denuder captures reactive mercury while allowing elemental mercury to pass through. During the sampling (adsorption) phase, the Model 2537 provides real time measurement of elemental mercury. During the analysis (desorption) phase, the denuder is flooded with Zero Air and heated. The captured reactive mercury is thermally desorbed and reduced to elemental form. The Model 2537 detects this eluted mercury, providing a measurement of total reactive mercury captured during the previous sampling period. The desorption process also regenerates the denuder coating. After cooling, the denuder is ready for another cycle. All timing parameters on the Model 1130 are programmable, allowing automatic RGM readings to be taken at user specified intervals.
 
Citation proposal
Pirrone N. (CNR-IIA, Institute of Atmospheric Pollution Research). Monte Curcio instruments. Tekran 1130 - Oxidized Mercury Speciation Module. CNR-Institute of Atmospheric Pollution Research https://geoportal.mountaingenius.org/geonetwork/srv/api/records/mcu_inst_tekran_1130_hg
 

Simple

Date ( Creation )
2015-02-25
Edition
First
Identifier
mt_curcio / mcu_inst_tekran_1130
Purpose
Assessment of environmental pollution

  Principal investigator

CNR-IIA, Institute of Atmospheric Pollution Research - Sprovieri F.  

  Custodian

CNR-IIA, Institute of Atmospheric Pollution Research - Pirrone N.  

  Publisher

CNR-Institute of Atmospheric Pollution Research - Pirrone N.  

Maintenance and update frequency
Not planned
GEOSS Societal Benefit Areas, version 2.3
  • Health
GEMET - INSPIRE themes, version 1.0
  • Environmental monitoring facilities , Human health and safety
GEMET - Concepts, version 2.4
  • pollution , pollutant
GEMET - Groups, version 2.4
  • CHEMISTRY, SUBSTANCES, PROCESSES
GEOSS - Earth Observation Vocabulary, version 1.0
  • ATMOSPHERIC CHEMISTRY , Contaminants/Pollutants (Inorganic/Organic)
GEOSS - Societal Benefit Areas, version 1.0
  • Global biogeochemistry , Human health , Pollution events
EARTh - Environmental Applications Reference Thesaurus
  • monitoring stations , pollution monitoring , environmental monitoring , monitoring network , air quality monitoring , pollutant monitoring
Use limitation
geossNoMonetaryCharge
Access constraints
Other restrictions
Other constraints
(e) intellectual property rights
Spatial representation type
Vector
Denominator
1000
Metadata language
English
Character set
UTF8
Topic category
  • Environment
  • Health
N
S
E
W


Time period
2015-01-012015-01-01
Reference system identifier
EPSG 4326

 

Date ( Revision )
2009-10-15

Distribution format
  • unknown (unknown )

OnLine resource
Browser to MCU databases  
OnLine resource
http://sdi.iia.cnr.it/mcugeoserver/ows?  
OnLine resource
http://sdi.iia.cnr.it/gmosgeoserver/ows?  
Hierarchy level
Dataset

Conformance result

Date ( Publication )
2009-06-11
Explanation
See the referenced specification
Pass
true
Statement
The Tekran 2537 and 1130 pump module are housed in a sheltered, mercury-free (less than 15 ng/m3), temperature controlled structure (15ºC -30ºC) [3]. Outside the shelter, the inlet of 1130/1135 system is positioned such that the inlet is ≤ 45° from vertical objects and trees, and ≤ 30° from buildings [5,6]. The parameter settings is established as below. The Autocal feature is set to “Yes” to indicate that the internal permeation source used for automatic calibrations is chosen. Sample timing in set at 5-minute sampling interval.//Ref. Operation manual Model 1130 (http://www.tekran.com) and GMOS SOPs (http://www.gmos.eu)

gmd:MD_Metadata

File identifier
mcu_inst_tekran_1130_hg   XML
Metadata language
English
Character set
UTF8
Hierarchy level
Dataset
Date stamp
2015-06-12T10:07:48
Metadata standard name
ISO 19115:2003/19139
Metadata standard version
1.0

  Originator

CNR-Institute of Atmospheric Pollution Research - Cinnirella S.  

 
 

  Overviews

  Provided by

  Share on social sites

         

  Views

  • INSPIRE
  • Simple
  • Full
  • XML
mcu_inst_tekran_1130_hg   Access to the portal Read here the full details and access to the data.

  Associated resources

Not available


  •  
  •  
  • API