Monte Curcio instruments. API 100E - Sulphur Dioxide Analyser
Monte Curcio (MCU) instruments: API Teledyne 100E sulphur dioxide analyser. The Model 100E is an analyser that determines the concentration of sulphur dioxide (SO2) in a sample gas drawn through the instrument’s sample chamber where it is exposed to ultraviolet light causing any SO2 present to fluoresce.
|
Citation proposal
Pirrone N. (CNR-IIA, Institute of Atmospheric Pollution Research). Monte Curcio instruments. API 100E - Sulphur Dioxide Analyser. CNR-Institute of Atmospheric Pollution Research https://geoportal.mountaingenius.org/geonetwork/srv/api/records/mcu_inst_api_100e_so2 |
Simple
- Date ( Creation )
- 2015-02-25
- Edition
- First
- Identifier
- mt_curcio / mcu_inst_api_100e_so2
- Purpose
- Assessment of environmental pollution
Principal investigator
- Maintenance and update frequency
- Not planned
- GEOSS Societal Benefit Areas, version 2.3
-
- Health
- GEMET - INSPIRE themes, version 1.0
-
- Environmental monitoring facilities , Human health and safety
- GEMET - Concepts, version 2.4
-
- pollution , pollutant
- GEMET - Groups, version 2.4
-
- CHEMISTRY, SUBSTANCES, PROCESSES
- GEOSS - Earth Observation Vocabulary, version 1.0
-
- ATMOSPHERIC CHEMISTRY , Contaminants/Pollutants (Inorganic/Organic)
- GEOSS - Societal Benefit Areas, version 1.0
-
- Global biogeochemistry , Human health , Pollution events
- EARTh - Environmental Applications Reference Thesaurus
-
- monitoring stations , pollution monitoring , environmental monitoring , monitoring network , air quality monitoring , pollutant monitoring
- Use limitation
- geossNoMonetaryCharge
- Access constraints
- Other restrictions
- Other constraints
- (e) intellectual property rights
- Spatial representation type
- Vector
- Denominator
- 1000
- Metadata language
- English
- Character set
- UTF8
- Topic category
-
- Environment
- Health
N
S
E
W
))
- Time period
- 2015-01-012015-01-01
- Reference system identifier
-
EPSG 4326
- Date ( Revision )
- 2009-10-15
- Distribution format
-
- unknown (unknown )
- OnLine resource
- Browser to MCU databases
- OnLine resource
- http://sdi.iia.cnr.it/mcugeoserver/ows?
- OnLine resource
- http://sdi.iia.cnr.it/gmosgeoserver/ows?
- Hierarchy level
- Dataset
Conformance result
- Date ( Publication )
- 2009-06-11
- Explanation
- See the referenced specification
- Pass
- true
- Statement
- Calibration of the instrument is performed in software that stores SO2 concentration measurements made when specific, known concentrations of SO2 are supplied to the analyser. The microprocessor uses these calibration values along with other performance parameters such as the sensor offset, UV lamp intensity, the amount of stray light present, and measurements of the temperature and pressure of the sample gas to compute the final SO2 concentration.//Ref. Operation manual Model 100E (http://www.teledyne-api.com/manuals/)
gmd:MD_Metadata
- File identifier
- mcu_inst_api_100e_so2 XML
- Metadata language
- English
- Character set
- UTF8
- Parent identifier
- b123e1e2-95d7-46c1-a476-b2de45c8fc33
- Hierarchy level
- Collection hardware
- Date stamp
- 2015-06-19T17:44:07
- Metadata standard name
- ISO 19115:2003/19139
- Metadata standard version
- 1.0
Overviews
Provided by

Views
mcu_inst_api_100e_so2
Access to the portal
Read here the full details and access to the data.