  Lukla air temperature

At the Lukla AWS the DMA572 Lsi-Lastem Thermohygrometer is mounted on a 2 m pole.

It is a probe for measuring air temperature and air relative humidity with replaceable sensitive element for simplify calibration and maintenance. LSI-Lastem supplies a precise and reliable set of probes, suitable for a continuous measurement in severe environments, in presence of deep thermal and hygrometric ranges with high sun radiant heat. An important feature of this set of sensor is that the thermohygrometric sensitive element is easily replaceable, in order to have a simple and rapid ordinary maintenance and avoiding calibration. The Thermohygrometer has supported a considerable improvement, owing to a deep technical and styling development process: a fan ensures a continuos air change around the sensor in order to eliminate temperature fault caused by radiant heat.

 
Citation proposal
(2011) . Lukla air temperature. https://geoportal.mountaingenius.org/geonetwork/srv/api/records/ef5dfddb-459f-4b0b-b1d5-722bec40ef6f
 
  • INSPIRE
  • SDS

INSPIRE

Identification

File identifier
ef5dfddb-459f-4b0b-b1d5-722bec40ef6f   XML
Hierarchy level
Series
Online resource
Protocol
WWW:DOWNLOAD-1.0-http--download
Protocol
WWW:LINK-1.0-http--partners
Resource identifier
Encoding
Projection
code
WGS 84 (EPSG:4326)
 

Classification of data and services

Topic category
  • Climatology, meteorology, atmosphere
  • Environment
  • Geoscientific information
 

Classification of data and services

Coupled resource
Coupled resource
 
 

Classification of data and services

Coupled resource
Coupled resource
 
 

Keywords

Other keywords
Keywords
  • SHARE , Network , Station , High Altitude
Keywords
  • CEOP
Keywords ( Place )
  • Lukla , Nepal , Khumbu Valley , Sagarmatha National Park
Keywords ( Theme )
  • AWS
Keywords ( Theme )
  • air temperature , relative humidity
 
 

Geographic coverage

N
S
E
W


 

Temporal reference

Temporal extent
Temporal extent
Date ( Publication )
2011-03-30T17:51:00
 

Quality and validity

Lineage

The station is included in the project of Share International CEOP (Co-ordinated Enhanced Obervation Period) World Meteorological Organization (WMO), which periodically collects data on the climate. The automatic weather stations (AWS) for monitor meteorological conditions are currently included in the SHARE network. An automatic weather station (AWS) is defined as a “meteorological station at which observations are made and transmitted automatically” (WMO, 1992a). In particular, in the framework of the SHARE project for all parameters, the data has been visually checked, looking for extremely and unusual low/high values and/or periods with constant values. The AWS in Lukla is a reference site in CEOP (Coordinated Energy and water Cycle Observation Project) under the WMO's initiative World Climate Research Programme (WCRP) - Global Energy and Water cycles Experiment (GEWEX).At the Lukla AWS the DMA572 Lsi-Lastem Thermohygrometer is mounted on a 2 m pole. It is a probe for measuring air temperature and air relative humidity with replaceable sensitive element for simplify calibration and maintenance. LSI-Lastem supplies a precise and reliable set of probes, suitable for a continuous measurement in severe environments, in presence of deep thermal and hygrometric ranges with high sun radiant heat. An important feature of this set of sensor is that the thermohygrometric sensitive element is easily replaceable, in order to have a simple and rapid ordinary maintenance and avoiding calibration. The Thermohygrometer has supported a considerable improvement, owing to a deep technical and styling development process: a fan ensures a continuos air change around the sensor in order to eliminate temperature fault caused by radiant heat.

Specifications for temperature parameter:

Sensivite element:Pt 100 1/3 DIN-B

Sensivite element replacement: ML3021 Plug-in by connector

Accuracy (Repeatability+Hysteresis): ± 0,1°C (0°C)

Resolution:n.a.

Long term stability: n.a.

Temperature dependence (+6+45°C/11-90%rh): n.a.

Specifications for relative humidity:

Sensivite element: Capacitative

Sensivite element replacement: ML3021 Plug-in by connector

Accuracy (Repeatability+Hysteresis):1,5% (5÷95%, 23°C) - 2% (<5>95%, 23°C)

Resolution: 0,12%

Long term stability: <1% anno/year

Temperature dependence (+6+45°C/11-90%rh):Max +-1.5%

General Specification:

Operating temperature: -40°÷95°C

Temperature dependence (+6+45°C/11-90%rh):

Power supply: 10÷14 Vdc/Vdc

Power consumption: 2 mA

Weight (cable attached):440 gr Weight

 

Conformity

Conformity
Conformity
 

Conformity

Conformity
Conformity
 

Restrictions on access and use

Access constraints
 

Restrictions on access and use

 

Responsible organization (s)

Contact for the resource
Organisation name
Ev-K2-CNR
Email
evk2cnr@evk2cnr.org
 

Responsible organization (s)

Contact for the resource
Organisation name
Ev-K2-CNR
Email
evk2cnr@evk2cnr.org
 

Metadata information

Contact for the metadata
Organisation name
Ev-K2-CNR
Email
metadata@evk2cnr.org
Date stamp
2025-02-05T17:36:44
Metadata language
eng
Character set
UTF8
 
 

SDS

Conformance class 1: invocable

Access Point URL
Endpoint URL
Technical specification
 

Conformance class 2: interoperable

Coordinate reference system
 
Quality of Service
 
Access constraints
Limitation
 
Use constraints
Limitation
 
Responsible custodian
Contact for the resource
 
 

Conformance class 3: harmonized

 
 

  Overviews

evk2cnr__.png
evk2cnr__.png

  Provided by

  Share on social sites

         

  Views

  • INSPIRE
  • Simple
  • Full
  • XML
ef5dfddb-459f-4b0b-b1d5-722bec40ef6f   Access to the portal Read here the full details and access to the data.

  Associated resources

Not available


  •  
  •  
  • API