• SHARE GeoNetwork
  •  
  •    

  South Col Ultrasonic Anemometer WMT700

During the 2011 expedition, a prototype replaces the sensor installed during 2008 expedition. A prototype (LSI-Lastem) to support with other two sensors manufactured by VAISALA: WMT700 and WA15D7B. The WMT700 sensor is a robust and reliable ultrasonic anemometer. It measures surface wind, which is one of the key parameters for meteorology and aviation. The WMT700 series uses ultrasound to determine horizontal wind speed and direction.
 
Citation proposal
(2011) . South Col Ultrasonic Anemometer WMT700. https://geoportal.mountaingenius.org/geonetwork/srv/api/records/e3cdf346-b81d-411f-a6fa-867ec01f6ade
 
  • INSPIRE
  • SDS

INSPIRE

Identification

File identifier
e3cdf346-b81d-411f-a6fa-867ec01f6ade   XML
Hierarchy level
Series
Online resource
Protocol
WWW:DOWNLOAD-1.0-http--download
Resource identifier
Encoding
Projection
code
WGS 1984(EPSG:4326)
 

Classification of data and services

Topic category
  • Climatology, meteorology, atmosphere
  • Environment
  • Geoscientific information
 

Classification of data and services

Coupled resource
Coupled resource
 
 

Classification of data and services

Coupled resource
Coupled resource
 
 

Keywords

GEMET ( Theme )
  • thermal power plant
Other keywords
Keywords
  • SHARE , Network , Station , High Altitude
Keywords ( Place )
  • Nepal , Mt. Everest - South Col , Himalaya
Keywords ( Theme )
  • air , research , pollution , ecosystems , landscape , natural areas , climate
Keywords ( Theme )
  • monsoon , subtropical jet stream , stratospheric intrusions , real time
Keywords ( Theme )
  • AWS
Keywords ( Theme )
  • wind speed , wind direction
 
 

Geographic coverage

N
S
E
W


 

Temporal reference

Temporal extent
Temporal extent
Date ( Publication )
2011-03-30T17:51:00
 

Quality and validity

Lineage

In 2008 at South Col the CombiSD DNA022 sensor (LSI-Lastem, Italy) was installed. During the 2011 expedition, this sensor was replaced with a prototype (LSI-Lastem) to support with other two sensors manufactured by VAISALA: WMT700 and WA15D7B. The WMT700 sensor is a robust and reliable ultrasonic anemometer. It measures surface wind, which is one of the key parameters for meteorology and aviation. The WMT700 series uses ultrasound to determine horizontal wind speed and direction. The measurement is based on transit time, the time it takes for the ultrasound to travel from one transducer to another, depending on the wind speed. The transit time is measured in both directions for a pair of transducer heads. Using two measurements for each of the three ultrasonic paths at 60° angles to each other, the WMT700 computes the wind speed and direction. The wind measurement is calculated in a way that completely eliminates the effects of altitude, temperature and humidity.

WMT700 Technical characteristic:

Wind Speed

Measurement range: uo to 75 m/s

Accuracy: +/- 0.2 m/s or 3 % of reading, whichever is greater

Starting threshold: 0.01 m/s

Resolution: 0.01 m/s

Wind direction

Measurement range: 0 to 360°

Accuracy: ±2°

Starting threshold: 0.1 m/s

Resolution: 1°

 

Conformity

Conformity
Conformity
 

Conformity

Conformity
Conformity
 

Restrictions on access and use

Access constraints
 

Restrictions on access and use

 

Responsible organization (s)

Contact for the resource
Organisation name
Ev-K2-CNR
Email
evk2cnr@evk2cnr.org
Organisation name
Institute of Atmospheric Sciences and Climate (ISAC) - CNR
Email
p.bonasoni@isac.cnr.it
 

Responsible organization (s)

Contact for the resource
Organisation name
Ev-K2-CNR
Email
evk2cnr@evk2cnr.org
Organisation name
Institute of Atmospheric Sciences and Climate (ISAC) - CNR
Email
p.bonasoni@isac.cnr.it
 

Metadata information

Contact for the metadata
Organisation name
Ev-K2-CNR
Email
metadata@evk2cnr.org
Date stamp
2025-02-04T15:30:03
Metadata language
eng
Character set
UTF8
 
 

SDS

Conformance class 1: invocable

Access Point URL
Endpoint URL
Technical specification
 

Conformance class 2: interoperable

Coordinate reference system
 
Quality of Service
 
Access constraints
Limitation
 
Use constraints
Limitation
 
Responsible custodian
Contact for the resource
 
 

Conformance class 3: harmonized

 
 

  Overviews

EVK2CNR
thumbnail

  Provided by

  Share on social sites

         

  Views

  • INSPIRE
  • Simple
  • Full
  • XML
e3cdf346-b81d-411f-a6fa-867ec01f6ade   Access to the portal Read here the full details and access to the data.

  Associated resources

Not available


  •  
  •  
  • API