• SHARE GeoNetwork
  •  
  •    

  Pyramid Heat Flux sensor

At the Pyramid Laboratory - Observatory the DPE260 Lsi-Lastem Heat flux sensor is installed.

Heat flux sensors are used for measuring thermal flux, i.e. the quantity of energy that passes through the sensor itself.

 
Citation proposal
(2011) . Pyramid Heat Flux sensor. https://geoportal.mountaingenius.org/geonetwork/srv/api/records/e37f5932-2761-49b4-a7c3-267c7388db23
 

Simple

Date ( Publication )
2011-03-30T17:51:00
Purpose

The purpose of this resource is to acquire data on:

- Soil Heat Flux

Status
Completed

  Point of contact

Ev-K2-CNR  
Via San Bernardino 145 Bergamo BG 24126 Italy

  +39 035 3230511  
  +39 035 3230551 
Website
http://www.evk2cnr.org/  
Maintenance and update frequency
As needed
GEMET ( Theme )
  • thermal power plant
Keywords
  • SHARE , Network , Station , High Altitude
Keywords ( Place )
  • Nepal , Lobuche , Khumbu Valley , Sagarmatha National Park
Keywords ( Theme )
  • AWS
Keywords ( Theme )
  • soil heat flux
Use limitation
No conditions apply
Access constraints
Copyright
Other constraints
Character set
UTF8
Topic category
  • Climatology, meteorology, atmosphere
  • Environment
  • Geoscientific information
N
S
E
W


Supplemental Information
Reference system identifier
EPSG / WGS 84 (EPSG:4326) / 7.4
Topology level
Geometry only
Geometric object type
Point
Geometric object count
1
OnLine resource
Himalayas Reference Site Pyramid Station  

Himalayas Reference Site Pyramid Station

OnLine resource
https://geoportal.mountaingenius.org/geonetwork/srv/api/records/e37f5932-2761-49b4-a7c3-267c7388db23/attachments/Data%20Usage%20Policy.pdf  
OnLine resource
https://geoportal.mountaingenius.org/portal/index.php/data/  
Hierarchy level
Series
Other
Data: soil heat flux
Statement

At the Pyramid Laboratory - Observatory the DPE260 Lsi-Lastem Heat flux sensor is installed.

Heat flux sensors are used for measuring thermal flux, i.e. the quantity of energy that passes through the sensor itself.

A thermopile, inserted within the heat flux, measures the small temperature difference that forms between its two sides due to thermal resistance. These sensors have direct outputs and are supplied with calibration certificates.

The technical characteristics are:

- Sensitive element: Thermopile

- Measurement range: <2000 Wm-2

- Electric output: 8..14 Wm-2

- Impedance: 400..500 ohm

- Accuracy: 3%

- Non-linearity: <1,5%

- Th.drift (-10+40°): <2%

- Response time (63%): 2min 5 min

- Operative temp: -40°+80°C.

- Therm. Conductivity: 0,5 W/m°C

- Thickness: 7 mm

- Ø total: 50 mm

- Ø active :15mm

- Output cable: 2 mt

- Weight (no cable): 50 gr

gmd:MD_Metadata

File identifier
e37f5932-2761-49b4-a7c3-267c7388db23   XML
Metadata language
eng
Character set
UTF8
Parent identifier
1802972c-49fa-4ddc-9622-4b50b858d7fd
Hierarchy level
Series
Date stamp
2025-02-07T16:25:46
Metadata standard name
ISO 19115:2003/19139
Metadata standard version
1.0

  Point of contact

Ev-K2-CNR  
Via San Bernardino 145 Bergamo BG 24126 Italy

  +39 035 3230511  
  +39 035 3230551 
Website
http://www.evk2cnr.org  
 
 

  Overviews

evk2cnr__.png
evk2cnr__.png

  Provided by

  Share on social sites

         

  Views

  • INSPIRE
  • Simple
  • Full
  • XML
e37f5932-2761-49b4-a7c3-267c7388db23   Access to the portal Read here the full details and access to the data.

  Associated resources

Not available


  •  
  •  
  • API