Surface Ozone
Surface Ozone Concentration unit[ppbv] is measured by using a UV-absorption analyser ( TEI 49C UV Analyzer).
|
Citation proposal
(2011) . Surface Ozone. https://geoportal.mountaingenius.org/geonetwork/srv/api/records/a48a8d09-7db3-4f5a-bf53-270aded137db |
INSPIRE
Identification
- File identifier
- a48a8d09-7db3-4f5a-bf53-270aded137db XML
- Hierarchy level
- Series
Online resource
- Protocol
- WWW:LINK-1.0-http--link
- Protocol
- WWW:LINK-1.0-http--related
- Protocol
- WWW:LINK-1.0-http--related
- Protocol
- WWW:DOWNLOAD-1.0-http--download
- Protocol
- WWW:LINK-1.0-http--partners
- Protocol
- WWW:LINK-1.0-http--link
- Protocol
- WWW:LINK-1.0-http--partners
Resource identifier
Encoding
Projection
- code
- WGS 1984
Classification of data and services
- Topic category
-
- Climatology, meteorology, atmosphere
- Geoscientific information
- Environment
Classification of data and services
Coupled resource
Coupled resource
Classification of data and services
Coupled resource
Coupled resource
Keywords
Other keywords
- Keywords
-
- SHARE , Network , Station , High Altitude
- Keywords
-
- WMO , GAWSIS , GAW
- Keywords
-
- CEOP , ABC
- Keywords ( Place )
-
- Nepal , Himalaya
- Keywords ( Theme )
-
- ozone
- Keywords ( Theme )
-
- air , research , pollution , ecosystems , landscape , natural areas , climate
Geographic coverage
N
S
E
W
))
Temporal reference
Temporal extent
Temporal extent
- Date ( Publication )
- 2011-04-01T19:01:00
Quality and validity
- Lineage
- Continuous O3 observations at the Nepal Climate Observatory - Pyramid (NCO-P, 5079ma.s.l., Nepal) GAW-WMO station. The measurement method used is Light absorption analysis (UV): Air sampling observation. The air is sampled by a 1m long intake at 3.5 m height above the ground. The air intake is a inox-steel pipe. A Teflon sampling line (lenght 1.5m) connects the air intake with the analyser. Data are first stored on a 1-minute basis and finally validated as 30-minute average values. The sampling methodology was based on the GAW-WMO requirements (GAW, 1992). The ozone measurement is usually expressed as mixing ratio, which requires a measure of the temperature and pressure within the sample chamber. Ozone monitors usually include these measurements and do the mixing ratio calculation automatically. The data are normally submitted as 30 minutes averages and deposited into the WDCSO at NILU, usually once a month.
Conformity
Conformity
Conformity
Conformity
Conformity
Conformity
Restrictions on access and use
- Access constraints
Restrictions on access and use
Responsible organization (s)
Contact for the resource
Responsible organization (s)
Contact for the resource
Metadata information
Contact for the metadata
- Organisation name
- National Research Council (CNR)- Institute for Atmospheric Science and Climate (ISAC )
- p.bonasoni@isac.cnr.it
- Organisation name
- National Research Council (CNR) - Institute for Atmospheric Science (ISAC)
- Date stamp
- 2011-12-07T10:56:23
- Metadata language
- eng
- Character set
- UTF8
SDS
Conformance class 1: invocable
Access Point URL
Endpoint URL
Technical specification
Conformance class 2: interoperable
Coordinate reference system
Quality of Service
Access constraints
Limitation
Use constraints
Limitation
Responsible custodian
Contact for the resource
Conformance class 3: harmonized
Overviews

thumbnail

large_thumbnail
Provided by

Views
a48a8d09-7db3-4f5a-bf53-270aded137db
Access to the portal
Read here the full details and access to the data.
Associated resources
Not available