  Net radiometer

The CNR1 net radiometer by Kipp & Zonen is for applications requiring research-grade performance. The radiometer measures the energy balance between incoming short-wave and long-wave IR radiation versus surface-reflected short-wave and outgoing long-wave IR radiation. The CNR1 consists of a pyranometer and pyrgeometer pair that faces upward and a complementary pair that faces downward. The pyranometers and pyrgeometers measure short-wave and far infrared radiation, respectively. The CNR1 also includes an RTD to measure the radiometer’s internal temperature and a heater that can be used to prevent condensation.
 
Citation proposal
(2011) . Net radiometer. https://geoportal.mountaingenius.org/geonetwork/srv/api/records/91f47e1c-4660-4d91-a7d8-b5b3910af868
 

Simple

Date ( Publication )
2011-03-30T17:51:00
Purpose

This sensor CNR1 measures :

- incoming and reflected solar radiation (W/m2) up and down Kipp & Zonen CNR1 pyranometer;

Status
On going

  Point of contact

Ev-K2-CNR  
Via San Bernardino 145 Bergamo BG 24126 Italy

  +39 035 3230511  
  +39 035 3230551 
Website
http://www.evk2cnr.org/  
Maintenance and update frequency
As needed
GEMET ( Theme )
  • thermal power plant
Keywords
  • SHARE , Network , Station , High Altitude
Keywords
  • CEOP
Keywords ( Theme )
  • glacier , cryosphere , micro-meteorological parameters , climate , natural areas , ecosystems , landscape , research
Keywords ( Place )
  • Forni Glacier , Italy , Stelvio National Park , Alps , Ortles-Cevedale group
Use limitation
No conditions apply
Access constraints
Copyright
Other constraints
Character set
UTF8
Topic category
  • Climatology, meteorology, atmosphere
  • Environment
  • Geoscientific information
N
S
E
W


Supplemental Information
Reference system identifier
EPSG / WGS 84 (EPSG:4326) / 7.4
Topology level
Geometry only
Geometric object type
Point
Geometric object count
13
OnLine resource
SHARE Geonetwork portal  

SHARE Geonetwork portal

OnLine resource
cnr1.pdf  

User's Manual CNR1 radiometer

Hierarchy level
Series
Statement

The CNR1 net radiometer by Kipp & Zonen is for applications requiring research-grade performance. The radiometer measures the energy balance between incoming short-wave and long-wave IR radiation versus surface-reflected short-wave and outgoing long-wave IR radiation. The CNR1 consists of a pyranometer and pyrgeometer pair that faces upward and a complementary pair that faces downward. The pyranometers and pyrgeometers measure short-wave and far infrared radiation, respectively. The CNR1 also includes an RTD to measure the radiometer’s internal temperature and a heater that can be used to prevent condensation.

CNR1 Specifications

Sensors: Kipp & Zonen’s CM3 ISO-class, thermopile pyranometer, CG3 pyrgeometer, PT100 RTD

Spectral Response

-Pyranometer: 305 to 2800 nm

-Pyrgeometer: 5000 to 50,000 nm

Response Time: 18 seconds

Sensitivity Range: 7 to 15 ?V W-1 m2

Output Range

-Pyranometer: 0 to 25 mV

-Pyrgeometer: ±5 mV

Expected Accuracy for Daily Totals: ±10%

Directional Error: <25 W m-2 (pyranometer)

Heating Resistor: 24 Ohms, 6 W at 12 Vdc

CE Compliance: CE compliant under the European Union’s EMC directive

gmd:MD_Metadata

File identifier
91f47e1c-4660-4d91-a7d8-b5b3910af868   XML
Metadata language
eng
Character set
UTF8
Parent identifier
5532e77c-dcb4-4c73-8d09-1cac44c1471e
Hierarchy level
Series
Date stamp
2011-11-28T12:46:39
Metadata standard name
ISO 19115:2003/19139
Metadata standard version
1.0

  Point of contact

Ev-K2-CNR  
Via San Bernardino 145 Bergamo BG 24126 Italy

  +39 035 3230511  
  +39 035 3230551 
Website
http://www.evk2cnr.org  
 
 

  Overviews

thumbnail
large_thumbnail

  Provided by

  Share on social sites

         

  Views

  • INSPIRE
  • Simple
  • Full
  • XML
91f47e1c-4660-4d91-a7d8-b5b3910af868   Access to the portal Read here the full details and access to the data.

  Associated resources

Not available


  •  
  •  
  • API