• SHARE GeoNetwork
  •  
  •    

  Pyramid air temperature

At the Pyramid Laboratory Observatory AWS the DMA570 Lsi-Lastem Thermohygrometer is mounted on a 2 m pole.

It is a probe for measuring air temperature and air relative humidity with replaceable sensitive element for simplify calibration and maintenance.

 
Citation proposal
(2011) . Pyramid air temperature. https://geoportal.mountaingenius.org/geonetwork/srv/api/records/71a5f1cb-e9e0-44f1-8e5d-aa1adc8ed49c
 
  • INSPIRE
  • SDS

INSPIRE

Identification

File identifier
71a5f1cb-e9e0-44f1-8e5d-aa1adc8ed49c   XML
Hierarchy level
Series
Online resource
Protocol
WWW:LINK-1.0-http--partners
Protocol
WWW:LINK-1.0-http--link
Protocol
WWW:DOWNLOAD-1.0-http--download
Resource identifier
Encoding
Projection
code
WGS 84 (EPSG:4326)
 

Classification of data and services

Topic category
  • Climatology, meteorology, atmosphere
  • Environment
  • Geoscientific information
 

Classification of data and services

Coupled resource
Coupled resource
 
 

Classification of data and services

Coupled resource
Coupled resource
 
 

Keywords

GEMET ( Theme )
  • thermal power plant
Other keywords
Keywords
  • SHARE , Network , Station , High Altitude
Keywords ( Place )
  • Nepal , Lobuche , Khumbu Valley , Sagarmatha National Park
Keywords ( Theme )
  • AWS
Keywords ( Theme )
  • air temperature , relative humidity
 
 

Geographic coverage

N
S
E
W


 

Temporal reference

Temporal extent
Temporal extent
Date ( Publication )
2011-03-30T17:51:00
 

Quality and validity

Lineage

At the Pyramid Laboratory Observatory AWS the DMA570 Lsi-Lastem Thermohygrometer is mounted on a 2 m pole.

It is a probe for measuring air temperature and air relative humidity with replaceable sensitive element for simplify calibration and maintenance. LSI-Lastem supplies a precise and reliable set of probes, suitable for a continuous measurement in severe environments, in presence of deep thermal and hygrometric ranges with high sun radiant heat. An important feature of this set of sensor is that the thermohygrometric sensitive element is easily replaceable, in order to have a simple and rapid ordinary maintenance and avoiding calibration. The Thermohygrometer has supported a considerable improvement, owing to a deep technical and styling development process: a fan ensures a continuos air change around the sensor in order to eliminate temperature fault caused by radiant heat.

For temperature:

Range -30.+70°C

Sensitive element Pt100 1/3 DIN-B

Accuracy ± 0,1°C (0°C)

Hysteresis&Repeatability na

Resolution 0,025°C

Long term stability -0.04% (after 5 years at 200°C)

Calibration uncertainty 0,1°C

Response time (T63) Wind speed 0,3-0,5 m/s: 80sec

Radiation shield efficiency with respect to forced ventilation sensor (wind 0,5m/s, rad.800 W/m2): +0,6°C

For relative humidity:

Range: Nom.0..100%, Eff.10..98%

Sensitive element Capacitive

Accuracy 2,5% (11-90%) 0,6°C (20°C, 50%RH)

Hysteresis&Repeatability 0,5%

Resolution 0,2%

Long term stability -2%/year (at 75%RH) n.a.

Calibration uncertainty 0,1°C 1,5% na

Response time (T63) Wind speed 0,3-0,5 m/s: 80sec

Radiation shield efficiency with respect to forced ventilation sensor (wind 0,5m/s, rad.800 W/m2): n.a.

General characteristic:

Ventilation: Natural

Electric output Jumper locally selectable 2 x 0-20 mA, 4-20 mA, 0-5 V, 1-5 V. 60-300 mV

Output signals Output n.1: temperature. Output n.2: RH% or dew point (default RH%)

Operating temperature -30°+70°C

Sampling rate 1 sec. (default) PC programmable 1..300 sec.

N°acquisitions for mobile average calculation: N°1 (default), PC programmable 1..20 acquisitions

Load resistance (mA output): DMA570 300 Ohm

 

Conformity

Conformity
Conformity
 

Conformity

Conformity
Conformity
 

Restrictions on access and use

Access constraints
 

Restrictions on access and use

 

Responsible organization (s)

Contact for the resource
Organisation name
Ev-K2-CNR
Email
evk2cnr@evk2cnr.org
 

Responsible organization (s)

Contact for the resource
Organisation name
Ev-K2-CNR
Email
evk2cnr@evk2cnr.org
 

Metadata information

Contact for the metadata
Organisation name
Ev-K2-CNR
Email
metadata@evk2cnr.org
Date stamp
2025-02-07T16:36:07
Metadata language
eng
Character set
UTF8
 
 

SDS

Conformance class 1: invocable

Access Point URL
Endpoint URL
Technical specification
 

Conformance class 2: interoperable

Coordinate reference system
 
Quality of Service
 
Access constraints
Limitation
 
Use constraints
Limitation
 
Responsible custodian
Contact for the resource
 
 

Conformance class 3: harmonized

 
 

  Overviews

evk2cnr__.png
evk2cnr__.png

  Provided by

  Share on social sites

         

  Views

  • INSPIRE
  • Simple
  • Full
  • XML
71a5f1cb-e9e0-44f1-8e5d-aa1adc8ed49c   Access to the portal Read here the full details and access to the data.

  Associated resources

Not available


  •  
  •  
  • API