  South Col Thermohygrometer DMA572

In 2008 expedition, at South Col was installed the DMA572 termohygrometer, that was replaced during the 2011 expedition with two DMA672 termohygrometers and one DMA033 thermometer. All these sensors are manufactered by LSI-Lastem (Italy).

DMA 672 thermohygrometer is an instrument for measuring temperature and relative humidity and suitable for a continuous measurement in severe environments; in presence of deep thermal and hygrometric ranges with high sun radiant heat.

 
Citation proposal
(2011) . South Col Thermohygrometer DMA572. https://geoportal.mountaingenius.org/geonetwork/srv/api/records/6f77696b-2e2c-4dd7-a423-453eaf7bc579
 
  • INSPIRE
  • SDS

INSPIRE

Identification

File identifier
6f77696b-2e2c-4dd7-a423-453eaf7bc579   XML
Hierarchy level
Series
Online resource
Protocol
WWW:DOWNLOAD-1.0-http--download
Resource identifier
Encoding
Projection
code
WGS 1984(EPSG:4326)
 

Classification of data and services

Topic category
  • Climatology, meteorology, atmosphere
  • Environment
  • Geoscientific information
 

Classification of data and services

Coupled resource
Coupled resource
 
 

Classification of data and services

Coupled resource
Coupled resource
 
 

Keywords

GEMET ( Theme )
  • thermal power plant
Other keywords
Keywords
  • SHARE , Network , Station , High Altitude
Keywords ( Place )
  • Nepal , Mt. Everest - South Col , Himalaya
Keywords ( Theme )
  • air , research , pollution , ecosystems , landscape , natural areas , climate
Keywords ( Theme )
  • monsoon , subtropical jet stream , stratospheric intrusions , real time
 
 

Geographic coverage

N
S
E
W


 

Temporal reference

Temporal extent
Temporal extent
Date ( Publication )
2011-03-30T17:51:00
 

Quality and validity

Lineage

Temperature & Relative humidity

Range -30 ÷ 70 °C ; 0 ÷ 100 %

Sensitive element: 1/3 DIN-B Pt 100 Capacitive

Sensitive element replacement: ML3021 plug-in by connector

Sensitive element accuracy (Repeatability + hysteresis):

±0,2 °C (0 °C);

1,5% (5 ÷ 95%, 23 °C)*

2%(<5, >95%, 23 °C)*

Electronic accuracy --- ±0.25%

Resolution 0,035°C 0.25%

Response time (sensitive element) :10s

Long term stability n.a. < 1% year

Temperature dependance

(6 ÷45 °C / 11 ÷90% RH)

n.a. Max ± 1,5%

Operating temperature -40 ÷ 95 °C

Output

DMA572: Pt100 (?)

DMA572: 0 ÷300 mV

DMA572.1: 0 ÷1 V

Power supply 10-14 Vdc

Power consumption 2mA

CE compliance EMC EN 61326-1 2006

Electric protections Tranzorb on outputs and power supply

Housing Plastic

Weight (cable attached) 440g

Connection cable 5m (attached)

 

Conformity

Conformity
Conformity
 

Conformity

Conformity
Conformity
 

Restrictions on access and use

Access constraints
 

Restrictions on access and use

 

Responsible organization (s)

Contact for the resource
Organisation name
Ev-K2-CNR
Email
evk2cnr@evk2cnr.org
Organisation name
Institute of Atmospheric Sciences and Climate (ISAC) - CNR
Email
p.bonasoni@isac.cnr.it
 

Responsible organization (s)

Contact for the resource
Organisation name
Ev-K2-CNR
Email
evk2cnr@evk2cnr.org
Organisation name
Institute of Atmospheric Sciences and Climate (ISAC) - CNR
Email
p.bonasoni@isac.cnr.it
 

Metadata information

Contact for the metadata
Organisation name
Ev-K2-CNR
Email
metadata@evk2cnr.org
Date stamp
2025-02-04T15:32:58
Metadata language
eng
Character set
UTF8
 
 

SDS

Conformance class 1: invocable

Access Point URL
Endpoint URL
Technical specification
 

Conformance class 2: interoperable

Coordinate reference system
 
Quality of Service
 
Access constraints
Limitation
 
Use constraints
Limitation
 
Responsible custodian
Contact for the resource
 
 

Conformance class 3: harmonized

 
 

  Overviews

EVK2CNR
thumbnail

  Provided by

  Share on social sites

         

  Views

  • INSPIRE
  • Simple
  • Full
  • XML
6f77696b-2e2c-4dd7-a423-453eaf7bc579   Access to the portal Read here the full details and access to the data.

  Associated resources

Not available


  •  
  •  
  • API