• SHARE GeoNetwork
  •  
  •    

  South Col Thermohygrometer DMA572

In 2008 expedition, at South Col was installed the DMA572 termohygrometer, that was replaced during the 2011 expedition with two DMA672 termohygrometers and one DMA033 thermometer. All these sensors are manufactered by LSI-Lastem (Italy).

DMA 672 thermohygrometer is an instrument for measuring temperature and relative humidity and suitable for a continuous measurement in severe environments; in presence of deep thermal and hygrometric ranges with high sun radiant heat.

 
Citation proposal
(2011) . South Col Thermohygrometer DMA572. https://geoportal.mountaingenius.org/geonetwork/srv/api/records/6f77696b-2e2c-4dd7-a423-453eaf7bc579
 

Simple

Date ( Publication )
2011-03-30T17:51:00
Purpose

Continuos measurement of Air Temperature [°C] and Relative Humidity[%] using a termohygrometer DMA572 during the 2008 expedition .

Measurements from this unique meteorological observatory can provide important information for the scientific community for several application, including weather forecasting and study related to the understanding climate change.

Status
Completed

  Point of contact

Ev-K2-CNR  
Via San Bernardino 145 Bergamo BG 24126 Italy

  +39 035 3230511  
  +39 035 3230551 
Website
http://www.evk2cnr.org/  

  Point of contact

Institute of Atmospheric Sciences and Climate (ISAC) - CNR - Paolo Bonasoni ( )  
Via Gobetti 101 Bologna BO 40129 Italy

  +39 051 639 9590  
  +39 051 639 9652 
Maintenance and update frequency
As needed
GEMET ( Theme )
  • thermal power plant
Keywords
  • SHARE , Network , Station , High Altitude
Keywords ( Place )
  • Nepal , Mt. Everest - South Col , Himalaya
Keywords ( Theme )
  • air , research , pollution , ecosystems , landscape , natural areas , climate
Keywords ( Theme )
  • monsoon , subtropical jet stream , stratospheric intrusions , real time
Use limitation
No conditions apply
Access constraints
Copyright
Other constraints
Character set
UTF8
Topic category
  • Climatology, meteorology, atmosphere
  • Environment
  • Geoscientific information
N
S
E
W


Supplemental Information
Reference system identifier
EPSG / WGS 1984(EPSG:4326) / 7.4
Topology level
Geometry only
Geometric object type
Point
Geometric object count
13
OnLine resource
https://geoportal.mountaingenius.org/geonetwork/srv/api/records/6f77696b-2e2c-4dd7-a423-453eaf7bc579/attachments/Data%20Usage%20Policy.pdf  
Hierarchy level
Series
Statement

Temperature & Relative humidity

Range -30 ÷ 70 °C ; 0 ÷ 100 %

Sensitive element: 1/3 DIN-B Pt 100 Capacitive

Sensitive element replacement: ML3021 plug-in by connector

Sensitive element accuracy (Repeatability + hysteresis):

±0,2 °C (0 °C);

1,5% (5 ÷ 95%, 23 °C)*

2%(<5, >95%, 23 °C)*

Electronic accuracy --- ±0.25%

Resolution 0,035°C 0.25%

Response time (sensitive element) :10s

Long term stability n.a. < 1% year

Temperature dependance

(6 ÷45 °C / 11 ÷90% RH)

n.a. Max ± 1,5%

Operating temperature -40 ÷ 95 °C

Output

DMA572: Pt100 (?)

DMA572: 0 ÷300 mV

DMA572.1: 0 ÷1 V

Power supply 10-14 Vdc

Power consumption 2mA

CE compliance EMC EN 61326-1 2006

Electric protections Tranzorb on outputs and power supply

Housing Plastic

Weight (cable attached) 440g

Connection cable 5m (attached)

gmd:MD_Metadata

File identifier
6f77696b-2e2c-4dd7-a423-453eaf7bc579   XML
Metadata language
eng
Character set
UTF8
Parent identifier
40f5a84c-83a4-4483-a083-b3431d3ffccd
Hierarchy level
Series
Date stamp
2025-02-04T15:32:58
Metadata standard name
ISO 19115:2003/19139
Metadata standard version
1.0

  Point of contact

Ev-K2-CNR  
Via San Bernardino 145 Bergamo BG 24126 Italy

  +39 035 3230511  
  +39 035 3230551 
Website
http://www.evk2cnr.org  
 
 

  Overviews

EVK2CNR
thumbnail

  Provided by

  Share on social sites

         

  Views

  • INSPIRE
  • Simple
  • Full
  • XML
6f77696b-2e2c-4dd7-a423-453eaf7bc579   Access to the portal Read here the full details and access to the data.

  Associated resources

Not available


  •  
  •  
  • API