• SHARE GeoNetwork
  •  
  •    

  Lukla Soil heat flux sensor

Heat flux sensor is used to measure thermal flux on the ground, i.e. the quantity of energy that passes through the sensor itself. A thermopile, inserted within the heat flux, measures the small temperature difference formed between its two sides, due to thermal resistance. These sensors have direct outputs and are supplied with calibration certificates. The sensor is put 5 cm below the surface. At the Lukla station the DPE260 Lsi-Lastem Heat flux sensor is installed.
 
Citation proposal
(2011) . Lukla Soil heat flux sensor. https://geoportal.mountaingenius.org/geonetwork/srv/api/records/3ee70eb5-bfd7-4d70-a4df-dd6a13076944
 

Simple

Date ( Publication )
2011-03-30T17:51:00
Purpose

The purpose of this sensor is to measure the following parameter:

- soil heat flux

The AWS in Lukla is a reference site in CEOP (Coordinated Energy and water Cycle Observation Project) under the WMO's initiative World Climate Research Programme (WCRP) - Global Energy and Water cycles Experiment (GEWEX).

Status
Completed

  Point of contact

Ev-K2-CNR  
Via San Bernardino 145 Bergamo BG 24126 Italy

  +39 035 3230511  
  +39 035 3230551 
Website
http://www.evk2cnr.org/  
Maintenance and update frequency
As needed
Keywords
  • SHARE , Network , Station , High Altitude
Keywords
  • CEOP
Keywords ( Place )
  • Lukla , Nepal , Khumbu Valley , Sagarmatha National Park
Keywords ( Theme )
  • AWS
Keywords ( Theme )
  • soil heat flux
Use limitation
No conditions apply
Access constraints
Copyright
Other constraints
Character set
UTF8
Topic category
  • Climatology, meteorology, atmosphere
  • Environment
  • Geoscientific information
N
S
E
W


Supplemental Information
Reference system identifier
EPSG / WGS 84 (EPSG:4326) / 7.4
Topology level
Geometry only
Geometric object type
Point
Geometric object count
1
OnLine resource
https://geoportal.mountaingenius.org/geonetwork/srv/api/records/3ee70eb5-bfd7-4d70-a4df-dd6a13076944/attachments/Data%20Usage%20Policy.pdf  
OnLine resource
Himalayas Reference Site Lukla Station  

Himalayas Reference Site

Lukla Station

Hierarchy level
Series
Other
Instruments: AWS sensors
Statement

At the Lukla station the DPE260 Lsi-Lastem Heat flux sensor is installed. Heat flux sensors are used for measuring thermal flux, i.e. the quantity of energy that passes through the sensor itself. A thermopile, inserted within the heat flux, measures the small temperature difference that forms between its two sides due to thermal resistance. These sensors have direct outputs and are supplied with calibration certificates.

The technical characteristics are:

- Sensitive element: Thermopile

- Measurement range: <2000 Wm-2

- Electric output: 8..14 Wm-2

- Impedance: 400..500 ohm

- Accuracy: 3%

- Non-linearity: <1,5%

- Th.drift (-10+40°): <2%

- Response time (63%): 2min 5 min

- Operative temp: -40°+80°C.

- Therm. Conductivity: 0,5 W/m°C

- Thickness: 7 mm

- Ø total: 50 mm

- Ø active :15mm

- Output cable: 2 mt - Weight (no cable): 50 gr

gmd:MD_Metadata

File identifier
3ee70eb5-bfd7-4d70-a4df-dd6a13076944   XML
Metadata language
eng
Character set
UTF8
Parent identifier
156cb588-270c-46a0-99ac-34fc19ab9a83
Hierarchy level
Series
Date stamp
2025-02-21T16:03:57
Metadata standard name
ISO 19115:2003/19139
Metadata standard version
1.0

  Point of contact

Ev-K2-CNR  
Via San Bernardino 145 Bergamo BG 24126 Italy

  +39 035 3230511  
  +39 035 3230551 
Website
http://www.evk2cnr.org  
 
 

  Overviews

evk2cnr__.png

  Provided by

  Share on social sites

         

  Views

  • INSPIRE
  • Simple
  • Full
  • XML
3ee70eb5-bfd7-4d70-a4df-dd6a13076944   Access to the portal Read here the full details and access to the data.

  Associated resources

Not available


  •  
  •  
  • API